4/60
              
               Siemens IK PI · 2015
              
               AS-Interface
              
               Slaves
              
               I/O modules for use in the field, high degree of protection
              
               Digital I/O modules IP67 – K45
              
               4
              
               ■
              
               Overview
              
               K45 compact modules
              
               The K45 series of compact modules supplements the large K60
              
               compact modules which have a proven track record in industry.
              
               They are the logical consequence for rounding off the bottom
              
               end of the existing product range.
              
               The acclaimed advantages of the existing K60 compact mod-
              
               ules are fully emulated by the K45 modules. The K45 modules,
              
               however, have a considerably smaller footprint and mounting
              
               depth.
              
               Yet in spite of these small dimensions all the modules have large
              
               labels and an integrated addressing socket.
              
               Two mounting plates are offered for the K45 compact modules:
              
               •
              
               The mounting plate for wall mounting has a hole pattern that is
              
               identical to that of the K60 compact modules. This means that
              
               K60 compact modules can be mounted together with K45
              
               modules in an aligned arrangement. The shaped cables can
              
               be inserted in the recesses of the mounting plates where they
              
               cause no hindrance.
              
               •
              
               The mounting plate for standard rail mounting
              
               Connection of the AS-Interface shaped cables
              
               The mounting plate and the compact module are joined together
              
               by means of a screw, with simultaneous contacting of the
              
               AS-Interface cable by the service-proven insulation piercing
              
               method.
              
               Now, mounting the AS-Interface shaped cables is in fact easier
              
               比以往任何时候都。黄色和黑色作为接口形状d cable can
              
               be inserted into the mounting plates from the left or right regard-
              
               less of the position of the coding lug. The correct polarity of the
              
               applied voltages is thus guaranteed.
              
               Addressing and connection of the sensors/actuators
              
               Addressing of the K45 compact modules is performed using an
              
               addressing socket integrated in the module. The addresses can
              
               be assigned even when mounted.
              
               K45 modules with a maximum of four digital inputs and outputs
              
               These compact modules contain up to four M12 standard
              
               connections or M8 standard connections for inputs and outputs.
              
               Using M12 or M8 standard connectors, a maximum of four
              
               sensors and four actuators can be connected to the compact
              
               module. Depending upon the module, the sockets can have a
              
               double assignment.
              
               Pin assignment: Y
              
               
              
               i.e. via a socket, two sensors or one sensor/
              
               one actuator is connected.
              
               K45 modules with a maximum of eight digital inputs
              
               These modules have eight digital inputs for connection through
              
               M12 plugs. The sockets have a double assignment
              
               Pin assignment: Y
              
               
              
               i.e. via a socket, two sensors or one sensor/
              
               one actuator is connected.
              
               The module requires two AS-Interface addresses for processing
              
               all eight inputs. The addresses can be assigned through a dou-
              
               ble addressing socket integrated in the module.
              
               K45 modules with four digital inputs and outputs/four digital
              
               outputs according to AS-i Specification 3.0
              
               The extended address mode (A/B addresses) according
              
               to AS-Interface Specification 3.0 enables the connection of up to
              
               62 slaves on one AS-i network. With this extended address
              
               mode, four outputs are now possible even with A/B slaves
              
               (instead of only three outputs possible up to now with Specifica-
              
               tion 2.1). Hence with full expansion of an AS-Interface network,
              
               现在有248的输入以及248输出available on one
              
               AS-Interface system.
              
               Please note, however,
              
               •
              
               that these modules can be used only with a master
              
               according to AS-i Specification 3.0
              
               •
              
               that the cycle times for the outputs may be up to 20 ms.
              
               Depending on the module, the sockets can have a double
              
               assignment. Pin assignment: Y
              
               
              
               i.e. via a socket, two sensors or
              
               one sensor/one actuator is connected.
              
               © Siemens AG 2014
              
             